G. S. I.
                      Inc.  G. S. I. Inc.                                                              Godfrey Systems International, Inc.
           Manufacturer & Distributor of Aerospace Lighting                   3051 Pine Street Clearwater, FL. 33763-0914 U. S. A.
                                                                   Tel: (727) 799-4916 Fax:(727) 724-0212
                                        E-Mail: Tim.Godfrey@gsilight.com, gsiinc@knology.net
HOME PRODUCTS WHAT'S NEW WHO WE ARE BUSINESS PARTNERS


CALIBER PHOTOMETRIC TESTING SYSTEM

                          Compliances:Caliber Photometric
                              Testing

ICAO Annex 14 Edition 2004,
FAA AC 150/5345-46C,
CENELEC, STAC



                                 Applications:


In order to deliver safety assurance and photometric performance, NAKSYS has created the CALIBER for establishing and maintaining an effective preventive maintenance program for airport visual aid facilities under the photometric requirement specified in ICAO Annex 14 Edition 2004 and FAA Circular AC 150/5345-46C.


                                                          Features:

Photometric TestingThis new generation of airfield photometric mobile measuring equipment uses light sensor technology to measure the performance of each light fitting installed on the runways and taxiways. In addition, a new feature offered by the CALIBER is the ability to vertically measure threshold, runway end, and stop bar lights. As the vehicle equipped with the Caliber System travels parallel to the device being measured, the sensor array converts into a vertical position. This unique feature reduces the measurement time on site from 40 minutes to 2 minutes for this type of aligned lights, and can measure all types of inset and elevated airfield lighting.


The CALIBER is a real-time integrated mobile equipment system.
Caliber
                              System



The CALIBER has been designed as an ergonomic, easy, and reliable product providing accurate photometric measurement and storage of information. Trending and analyzing the performance of light fittings on airfield runways and taxiways has never been made easier!





                                                       Specifications:

The following capabilities and performance of the CALIBER are just a few highlights:

Caliber Specifications

  Uses accurate photometric sensors to measure precise illumination of light beams. The accurate distance sensor records precise measurement data sample positions.

  Can easily be transferred to any vehicle without manufacturer assistance.

  Allows the operator to stop the light measurement process at any point, with the ability to start the process again from the last point. The system will automatically generate a single report at the end of measurement, despite multiple stops.


  Using a high speed sub-meter precision DGPS receiver unit, the system provides the option to automatically identify database numbers of each light fitting being measured.

  Compact and integrated system can be installed easily in any vehicle.

  Can easily be stored and transported using the specialized carrying cases.

  Instantaneous, on site options to view and print the measurement reports.

The open architecture in the design of the CALIBER system allows different types of material configurations, thus offering the airport users the desired operating methods for each individual airport need.

Caliber Photometric System

                                                            Software:

The standard version of the CALIBER software program includes all necessary functions to manage the following:

Caliber Software
  Airport details including information on runways and taxiways.

  Detailed list of the persons operating the system.

  Complete lights data base.

  Light measurement on site.

  Hardware diagnostics.

  Addition of measurement reports.




Join These Other Airfields That Use THE CALIBER SYSTEM
To Insure Their Lights Meet Photometric Requirements


◙   CALIBER System Users   
USA
Hartsfield-Jackson Atlanta International Airport
Indonesia
Indonesian Civil Aviation Authority
South Korea
Gimpo International Airport
United Arabs Emirates
Al Ain International Airport
United Arabs Emirates
AFM Group
Peru
Lima International Airport
Netherlands
Woensdrecht Air Base
France
Bordeaux International Airport
Belgium
JDC Airports
Belgium
Charleroi Brussels South International Airport
Ireland Belfast International Airport
Ireland Dublin International Airport
Maldives
Maldives International Airport
UAE
Dubai International Airport
UAE
Sharjah International Airport
UAE
Abu Al Abyad Private Airport
India Kolkatta International Airport
UK ATG Airports
UK
Blackpool International Airport
UK
Easy Midlands International Airport
UK
Newquay International Airport
Sweden Stockholm Arlanda International Airport

Airfield Photometry

The involvement of the CALIBER in an airfield can provide preventative maintenance, regular inspection, and service upkeep - cutting the costs of testing time and future repairs.

You will find that NAKSYS offers complete solutions in photometric testing of AGL systems to increase the safety
and efficiency for your airfield needs and operations.



                                                 Sold & Serviced in the United States & Canada by G. S. I. Inc.                                             
Manufactured by:

NAKSYS

NAKSYS
78 Rue Gabriel Peri  
◙   91330 Yerres   ◙   France
Tel:  + 33 (01) 69 48 93 19
  ◙   Fax:  + 33 (01) 69 43 55 08
E-mail:  contact@naksys.com   ◙   Website:  www.naksys.com

 Printable Version 

HOME PRODUCTS WHAT'S NEW WHO WE ARE BUSINESS PARTNERS

Wade PublishingCreated By KMPH - Web Architect, G. S. I. Inc.

             
Updated: December 3, 2012

     
©
1997-2013 All Rights Reserved
LinkedInPinterestFacebook